(1)阿特拉斯空压机中低压管路的法兰接,多采用焊接式法兰。其技术要求如下:
(a)法兰端面与管子中心线要垂直。用法兰尺检查。检查时用塞尺测量法兰尺与法兰端面的间隙(按圆周测量),此间隙就是法兰端面与管子中心线之间的垂直度偏差,(参考图1)

(b)一对对接法兰的端面之间应相互平行,其平行度偏差不大于图2中的数方向的沟槽及值。

(c)法兰密封面必须光滑,不许有辐射方向的沟槽以及沙眼等缺陷。
 安装带法兰的管路时,必须在两个对接法兰的密封间放置垫片。该垫片的内径不小于管子内径,其外径不大于法兰螺栓孔里圆的直径。安装时在垫片两面涂上一层密封胶,拧紧螺栓时应对称交叉进行。
(2)所有管路应按规定工作压力进行强度试验,试验压力为工作压力的1.5倍。管子内部应清理干净,不得有焊接、锈皮及沙泥土、等赃物。
(3)安装安全阀时,应使它处于垂直位置,调整安全阀的开启压力为工作压力的1.1倍。
(4)管道的管子支架与托架应有足够的强度和刚性。管子与支架接触处用木块或软金属板垫好。管子与管子之间或与其他物体之间的间隔距离应不小于30mm.
 (5)管子穿墙时,在管子外应有套管,并在套管与管子间充填绝缘物。
(6)管子的油漆颜色,按输送的不同流体而有所区别。阿特拉斯空压机管道涂刷浅蓝色;工业用水管道涂刷黑色;生活用水管道涂刷绿色。涂刷颜色时要将焊口代号留出,并以箭头表示流动走向。文章来源:(http://www.bjydss.com)
(1) Atlas compressor in low-pressure pipeline flange connection, the use of welded flange. Its technical requirements are as follows:
(a) the flange end face is perpendicular to the center line of the pipe. Check with flange. Check with the feeler gap size and flange flange surface (by circumference measurement), the vertical deviation between this gap is the end surface of the flange with the center line (see Figure 1).
(b) the face of a pair of butt flanges shall be parallel to each other, and the parallelism deviation shall not be greater than the number of grooves and values in Figure 2.
(c) flange sealing surface must be smooth, no radiation direction of the trench and the defects such as.
When installing the pipeline with flange, the gasket must be placed between the two butt flanges. The inner diameter of the gasket is not less than the inner diameter of the pipe, and the outside diameter of the gasket is not larger than the diameter of the circle diameter of the flange bolt hole. When mounting, the two sides of the gasket are coated with a layer of sealant.
(2) all piping shall be carried out in accordance with the working pressure of the working pressure, the test pressure is 1.5 times of the working pressure. The inside of the pipe should be cleaned up, without welding, rust and dirt, sand and other stolen goods.
(3) the installation of safety valve, should make it in a vertical position, adjust the safety valve opening pressure for the working pressure of 1.1 times.
(4) the pipe support and the bracket should have enough strength and rigidity. The contact tube and bracket with a piece of wood or soft metal plate pad. The distance between the pipe and the pipe or between the other objects shall be not less than 30mm.
(5) the pipe wall, the pipe outside the casing, and the casing and the pipe is filled between the insulating material.
(6) the paint color of the pipe, according to the different fluid transport. Atlas compressor pipeline coating industrial water pipe painted light blue; black; water pipes painted in green. When brushing the color of the welding port code set aside, and the direction of the arrow to indicate the flow direction.